Filter
–
Highlights:
Gigabit Ethernet (10/100/1000MBit/s)
IEEE 802.3ab compliant
4kVrms Dielectric strength
Galvanic isolation: Creepage distance: 12.8mm, Clearance distance: 12.2mm
no restrictions on cable length
ESD protection: suppression of transient overvoltages on the signal lines
suitable for devices with a supply voltage up to 250 Vrms
Not suitable for use with PoE devices
Dimensions 80x58x24mm
Plug&Play - no installation required
Compact and universally applicable
No permanently mounted cables
Robust housing
Suitable for all systems with one network connection
requires no power supply
APPLICATIONS:
DEVICE PROTECTION
Protection of especially valuable devices against hum and surge voltages from the network periphery.
MEASUREMENT TECHNOLOGY
Protection of electrical measuring and monitoring equipment against external and interference voltages from the Ethernet cabling.
POTENTIAL DIFFERENCES (BUILDING SERVICES ENGINEERING)
Prevention of equipotential bonding currents in computer systems which are connected by an Ethernet cabling are galvanically connected to each other over longer distances.
AUDIO
Reduction of low-frequency alternating voltages (network hum), which are caused by the network connection to an imperceptible degree.
Technical Details:
Dielectric strength signal and shield
5000 V 50/60 Hz over 1 min; 10.000 VDC over 10 s
Data throughput
10/100/1000 MBit/s
Connections
2x J45 input/output
Network specifications
IEEE 803.2 from 10/100/1000-BaseT, twisted pair, auto-conf. (behaves completely transparent in the network)
Material
94V-0/RoHS compliant/SvHC/REACH
Product Rating (UL)
Passive, electronic components, insulation level DI (250 VAC/300 VDC) tested at 4 kVAC
Operating mode
Continuous operation
Operating time between failures
0,21x 108 (1 failure in 21,000,000 h)
ESD
16 kV
DC Stress-Test (10 s)
10 kV
Return Loss
min. 10 dB
Insertion Loss
max. 1,3 dB
Dimensions (mm, LxWxH)
80 x 58 x 24, ca. 39 g
Standards
IEC 60601-1 1x MOPP up to 250Vrms (the built-in network transformer)
Environment
Operation and storage: -40...+70°C
10...75% rel. humidity
non-condensing