The Tekbox EMC compliance software EMCview for PCs is a user-friendly EMC pre-compliance testing of radiated and conducted emissions. It is a perfect complement for automated testing using our LISNs, RF current probes, measurement antennas and TEM Cells.
A built-in amplitude correction enables correction and conversion coefficients for cables, amplifiers, attenuators, LISNs, TEM cells, antennas, RF current probes, filters and any other component in the signal chain.
There is no need for a time-consuming setup. The SW is ready for measurements straight after installation. All emission related standards and a few automotive manufacturer standards are pre-configured in corresponding project files. The project files take care of all necessary settings to conduct standard compliant measurements. Besides using pre-configured projects, the user can easily create his own projects using a built in editor or any simple text editor.
The graph supports two complete measurement runs such as for example Average / Quasi-Peak or Peak / Quasi Peak and in addition a fast Quasi-Peak scan of critical peaks. Graphs can be saved and overlayed with newer measurements to track and document design modifications.
Furthermore, EMCview together with our GPS receiver can be used to carry out RF-coverage measurements. An export feature creates KML files which link the result to google maps.
Immunity testing is supported with dedicated menus, controlling the tracking generator of the spectrum analyzer.
EMCview PRO, offers real-time measurement support for spectrum analyzers with real-time capability. Furthermore, EMCview PRO offers advanced conducted immunity testing features for spectrum analyzers with tracking generators. The customer can select between a standard EMCview license or EMCview PRO. Users with a standard EMCview license have the option to upgrade to EMCview Pro.
Software limitation without a license: the measurement is limited to the frequency range below 10MHz
EMCview currently supports the following spectrum analyzers
Rigol (DSA and RSA)
Siglent (SSA/SSA plus/SSA -R and SVA) Siglent EU, Siglent USA
R&S (FPC and FPH)
OWON XSA, HSA and NSA
Teledyne Test Tools T3SA series
BK Precision 2683 series
ComPower SPA-900TG series
Multicomp MP700xyz series
TheEMCShop ESA series
UNI-T UTS series
The spectrum analyzer should be equipped with the EMI option.
Features
numerous pre-configured project files for CISPR-xx (EN550xx) emission measurements
graph supports two complete measurement runs, same as in test house
fast Quasi-Peak scan of critical peaks, immune to frequency drift of the selected peaks
configurable limit lines and segment files
configurable correction files for cable, LISN, amplifier, antenna etc.
configurable margins for the identification and selection of critical peaks
supports import and overlaying of reference measurements for comparison purpose
linear or logarithmic frequency axis
automatic creation of test reports
many import/export-functions
Applications
in house measurement of EMC behavior during product design phase
EMC training in lab, school and university
pre-compliance test of products before submitting it to the test house
test cost reduction
reduced time to market
Die TBBCI1-CAL ist eine Kalibriervorrichtung für die TBBCI1 Serie von Bulk Current Injection Sonden.
Die Kalibrier Vorrichtung wird in Kombination mit einem Vector Network Analyzer oder Spectrum Analyzer mit Mitlaufgenerator verwendet, um die Übertragungsimpedanz oder Einfügungsdämpfung von BCI-Sonden zu messen.
Jede Tekbox HF-Stromüberwachungssonde wird zusammen mit einem entsprechenden Kalibrierungsblatt geliefert, das die Werte der Einfügungsdämpfung und der Übertragungsimpedanz in Abhängigkeit von der Frequenz enthält.
Kalibrierungs Vorrichtungen können für die regelmäßige Inspektion der Sonden oder für Gesundheitschecks verwendet werden, falls eine Sonde heruntergefallen ist und der Verdacht besteht, dass der Ferritkern beschädigt wurde.
Darüber hinaus werden Kalibrier Vorrichtungen für die Kalibrierung von Prüfaufbauten für leitungsgebundene Störfestigkeit verwendet. Ausführliche Informationen zur Verwendung von Kalibrier Vorrichtungen für diesen Zweck finden Sie in der Applikation Note Conducted Immunity Basics.
Der Applikationsbericht kann von der Tekbox-Website heruntergeladen werden.