Temperature Transmitter SCD 45

für Pt, Ni, KTY, TC, R, potentiometer and mV sensors, programmable via USB and DIP switches

The programmable temperature transmitter SCD 45 is used for the acquisition of industrial process signals. It converts the measured values of Pt, Ni, KTY or TC sensors as well as potentiometers, resistors and mV signals into isolated standard signals.

  • Universal measurement input
    for all common industrial sensor signals
  • Simple configuration via USB or DIP switches
    completely programmable üvia USB interface or via DIP-switch switchable
  • >Switchable service functions
    Simulation and teach-in function for simple commissioning
  • 3-port separation
    Protection against measuring errors due to grounding problems and transmission of static voltage
  • Extremely narrow design
    6.2 mm narrow side-by-side housing for simple and space-saving top-hat rail mounting
  • Optional In-Rail Bus DIN Rail Bus Connector
    allows fast and cost-effective installation
  • Safe separation according to EN 61140
    Protection of maintenance personnel and downstream equipment against excessive voltage
  • 5 years warranty
    Defects occurring within 5 years of delivery will be remedied free of charge if delivered to the factory free of charge
  • .

The programmable temperature transmitter SCD 45 is used for the acquisition of industrial process signals. It converts the measured values of Pt, Ni, KTY or TC sensors as well as potentiometers, resistors and mV signals into isolated standard signals.

The simple programming via USB interface and alternatively the calibrated range switching via DIP switch make it flexible to use.

The front switchable commissioning function generates a reference signal at the output with which the following signal path can be tested and adjusted. With the teach-in function, the measuring range limits can be taught in during operation.

With the USB programming kit the transmitter can be configured via PC and the data can be stored and documented. An additional power supply is not necessary during programming.

The power can be supplied via the terminals or via the optional In-Rail-Bus. The supply voltage and error status is indicated by an LED on the front of the device.

Technical data

Input

Sensor Type Span min. Measuring error
  Pt Pt100, Pt200, Pt500, Pt1000 10 K <0,1K+0,05% v.M.
  Ni Ni100, Ni200, Ni500, Ni1000 10 K <0,2K+0,05% f.M.
  KTY KTY, 29 types 25 K <0,3K+0,05% f.M.
  Resistance 0 ... 5000 & Omega; 100 Ω <0,1Ω+0,02% f.M.
Sensor current / Sensor connection 0.2 mA / 4-wire, 3-wire, 2-wire
Line resistance < 100 Ω per conductor,
manual compensation for 2-wire connection programmable
 
  Thermocouples E, J, K, L, N, R, S, T, U
B, C, D
50K
100K
<0,3K+0,08% f.M.
<0,3K+0,08% F.S.
comparison junction compensation internal, external, uncompensated, manual default comparison junction error internal < 1,5 K
  mV input ±100 mV, ±1000 mV 5mV, 50mV <50µV+0,02% v.M.
  Potentiometer 100 Ω ... 50 kΩ 10 % < 0.05 %

Output

  Current Voltage
Output signal 0...20mA, 4...20mA, 0...10mA, 2...10mA 0...5V, 0...10V, 1...5V, 2...10V
Load ≤ 12 V      (600 Ω at 20 mA) ≤ 5 mA      (2 kΩ at 10 V)
Rest ripple < 10 mVeff
Transmission range 0...102.5 %,
(3.8...20.5 mA with output 4...20 mA)
characteristic rising / falling
Error signal sensor/wire break, signaling programmable

General data

Transmission error < 0.1 % of full scale value temperature coefficient1) < 100 ppm/K
Measurement rate / Response time T99 4/s / 250 ms
Pressure voltage 3 kV AC, 50 Hz, 1 min. Input against output against supply
Working voltage 2)
(basic insulation)
600 V AC/DC at overvoltage category II and pollution degree 2 acc. to DIN EN 61010-1
Protection against dangerous
body currents 2)
Secure separation according to DIN EN 61140 by reinforced insulation according to DIN EN 61010-1 up to 300 V AC/DC at overvoltage category II and pollution degree 2 between all circuits.
Ambient temperature Operation
Transport and storage
-25 °C to +70 °C
-40 °C to +85 °C
(-13 to +158 °F)
(-40 to +185 °F)
Auxiliary power 24 V DC 9.6 V...31.2 V DC, approx. 0.8 W
EMV 3) EN 61326-1
Approvals (pending) UL (USA/Canada): UL 61010, Class I, Div. 2
ATEX / IECEx: Zone 2 (nA)
Design 6.2 mm (0.244") Bayed enclosure, degree of protection: IP 20
Mounting on 35mm DIN rail acc. to EN 60715
Weight approx. 70 g

1)Mid Tk relative to the final value in the specified operating temperature range, reference temperature 23 °C

2)In applications with high working voltages, ensure that there is sufficient distance or insulation from secondary equipment and that contact protection is provided.

3)Wär during the normal effect small deviations may occur

Circuit diagram

Block diagram

Dimension drawing

Dimension drawing

terminal assignment

1   Input
2   Input
3   Input
4   Input
     
5 + Output
6 - Output
     
7 + Power supply
(bridged to In-Rail-Bus)
8 - Power supply
(bridged to In-Rail-Bus)

Connection

  • Captive plus-minus clamping screws
  • Connection cross-section max. 2.5 mm²
  • Abisolierlänge 6 … 8 mm
  • Tightening torque 0.8 Nm
  • Optional supply connection üvia In-Rail bus (see accessories)

 

 